Product

  • Union Adaptors UNY

    Application
    The main function of the system is to enable the two pipes to b e joined without rotation. The main function of the two pipes is explosion-proof lamps and explosion-proof boxes, and most of them are used for general pipe work.
Specification
Explosion proof execution Ex db IIC Gb, Ex tb IIIC Db IP66/IP65
IP66: 1/2"~3", IP65: 4
Certificate issued by TÜV Rheinland / TS mark
Material Ductile Iron-Zinc Electroplated / Ductile Iron-Powder Paint / D uctile iron-Hot Dip Galvanized /
Stainless Steel 304 / Stainless Steel 316
Designation part number system
1 2 3 4 5
Certification Unit Name of fitting Hub Size  Thread Standard Material
 
1  Certification Unit / Code
International Electrotechnical Commission  / IEC
2 Name of fitting / Code
UNF / UNY
2 Hub / Code
Hub Size 1/2" 3/4" 1 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"
Code 050 075 100 125 150 200 250 300 400
3 Thread Standards / Code
Thread Standards Code
NPT N
4  Material / Finish / Code
Material Finish Code
Ductile iron Zinc Electroplated E
Ductile iron Powder Paint E2
SUS304   S4
Ductile iron Hot Dip Galvanized H
SUS316   S6
 
Example
IEC UNY 075 N E2
Certification Unit Name of fitting Hub Size  Thread Standard Material
IEC Male &Female Union Adaptors 3/4" NPT Powder Paint
 
 
IEC UNF 250 N H
Certification Unit Name of fitting Hub Size & Type Thread Standard Material
IEC Female Union Adaptors 2-1/2" NPT Ductile
iron
 
Introduction
規格 Dimensions (mm)
Hub Size A B C
1/2" 39 53 40
3/4" 46 57 42
1" 51 71 52
1-1/4" 67 71 47
1-1/2" 74 69 53
2" 87 85 61
2-1/2" 106 95 70
3" 123 97 70
4" 146 110 80
· Tolerance: ±5% 
Instruction of UNY / UNF
A
Disassemble the union adaptors apart, and be aware of to pass
external threads (M) or internal threads (F) through cap nut (SM)
and tighten it on the jack of relevant box.
B Connect the wiring part with Y-type internal thread (FY).
C Tighten external threads (M) or internal threads (F) with Y-type
internal thread (FY) by using cap nut (SM), and make sure that
it is tightened well enough that external threads (M) or internal
threads (F) is unable to turn easily.
D While working, it needs to be aware of that the accessories and
related parts must all be vertical with the wiring, thus it will not
cause any possibility of damage on internal electric wires.
Product Consultation